Deye SUN-EVSE11K01-EU-AC
You charge your electric car at home, preferably from the panels' surplus: 11 kW three-phase, own 4.2 m cable attached, weather resistant (IP66).
Two cars charged at the same time from a single station body. 2 x 22 kW, 2 x 32 A at 400 V, two Type 2 sockets, IP54, IK10 and automatic power balancing.
This is the two-charging-point version of the cylindrical floor-standing station: two drivers can charge at the same time, each at their own socket, from a single post mounted on the floor. In practice, you double the capacity of a parking area without doubling the excavation, the foundations and the supply cables. The cars are connected with the users' own cables, as is customary in car parks used by several people.
The supply is three-phase at 400 V, with two circuits of 32 A each, that is 2 x 22 kW, up to 44 kW installed in a single body. So that you do not exceed the building's connection when both cars are charging at the same time, the station automatically shares the power between the two points. The cylindrical stainless steel enclosure is 114 mm in diameter and weighs 12 kg, so it stays discreet even with two active connections. For spaces with public access it has IP54 protection against dust and splashes, IK10 impact resistance and shock and tilt sensors that automatically stop charging in case of an incident; it operates from -30 to +60 °C. It connects to the internet through Wi-Fi, a network cable or its own 4G modem and can be integrated into a public charging network with centralised billing.
Code ACS1211: supply 3Ph + N + PE, 400 V, 2 x 32 A, maximum power 2 x 22 kW (44 kW total), two Type 2 sockets with shutter (T2S), cables not included, simultaneous charging of two vehicles, self standing installation. Cylindrical stainless steel enclosure, Ø 114 mm, weight 12 kg. Protection with type A RCBO 30 mA / 40 A on each circuit, residual current monitoring, protection against overcurrent, overvoltage, undervoltage and earth fault; IP54, IK10, shock and tilt sensors with automatic shutdown. Operation -30...+60 °C, humidity 5-95% non-condensing. Communication Wi-Fi 2.4 GHz, Bluetooth 5, Ethernet and 4G modem, with OCPP 1.6 (OCPP 2.0.1 in preparation), Modbus RTU, NFC and Plug & Charge ISO 15118-20; dynamic load balancing between the two points to stay within the connection limit and integration with photovoltaic systems. Compliance IEC 61851-1:2019, IEC 61851-21-2:2021, IEC 62196 Type 2 and EN 60529, CE marking, MID / Eichrecht option. 2-year warranty.
Suitable for office car parks, residential complexes and hotels, where charging demand is high and two spaces are to be served from a single infrastructure.
| Product code | ACS1211 |
|---|---|
| Maximum power | 2 x 22 kW (44 kW total) |
| Supply voltage | 3Ph + N + PE, 400 V |
| Maximum current | 2 x 32 A |
| Connectors | 2 x priza Type 2 cu obturator (T2S) |
| Charging cables | neincluse |
| Simultaneous charging | da, doua vehicule |
| Installation | pe pardoseala (self standing) |
| Enclosure diameter | Ø 114 mm |
| Weight | 12 kg |
| Residual current protection | RCBO tip A, 30 mA, 40 A |
| Mechanical protection | IP54 / IK10, senzori de soc si inclinare |
| Operating temperature | -30...+60 °C |
| Humidity | 5-95%, fara condens |
| Communication | Wi-Fi 2,4 GHz, Bluetooth 5, Ethernet, modem 4G |
| Protocols | OCPP 1.6 (2.0.1 in pregatire), Modbus RTU, NFC |
| Standards | IEC 61851-1:2019, IEC 61851-21-2:2021, IEC 62196, EN 60529, MID / Eichrecht |
2 years
Specifications confirmed from the manufacturer's datasheet
Astreea SmartCharger self standing dual (code ACS1211) is the two-charging-point version of the cylindrical floor-standing station. The supply is three-phase 3Ph + N + PE, 400 V, with two 32 A circuits and a maximum power of 2 x 22 kW, that is up to 44 kW installed in a single station body. The two vehicles can be charged simultaneously, which doubles the capacity of a parking space without doubling the infrastructure works.
The station is equipped with two Type 2 sockets with shutter (T2S), with no cables included - users use their own charging cables. The cylindrical stainless steel enclosure has a diameter of 114 mm and the height specific to the dual model, and the weight is 12 kg. Electrical protection is provided by a type A RCBO of 30 mA / 40 A on each circuit, with residual current monitoring and protection against overcurrent, overvoltage, undervoltage and earth fault. Mechanically, the station offers IP54 and IK10, with shock and tilt sensors and automatic shutdown in case of an incident.
It operates between -30 and +60 °C, at 5-95% humidity without condensation. Communication is through Wi-Fi 2.4 GHz, Bluetooth 5, Ethernet and 4G modem, with support for OCPP 1.6 (OCPP 2.0.1 in preparation), Modbus RTU, NFC and Plug & Charge ISO 15118-20. The station manages dynamic load balancing between the two points, so that the total power does not exceed the connection limit, and it can be integrated with photovoltaic systems. Compliance with IEC 61851-1:2019, IEC 61851-21-2:2021, IEC 62196 Type 2 and EN 60529, with CE marking and MID / Eichrecht option.