Deye RW-F16 battery, 16 kWh, LiFePo4
Autonomy for a whole evening: 16 kWh, of which 14.4 kWh usable, 160 A continuous and a 300 A peak for appliances that are hard to start.
A 5.12 kWh battery that can charge even in the cold, thanks to its own heating: extended operation down to -18 degrees C and over 6000 cycles.
Lithium batteries have a known weakness: at sub-zero temperatures they no longer accept charging, so that the cells are not damaged. This model solves the problem with an integrated heating film, which warms the cells before charging them. In practice, it can be installed in a garage, in an outbuilding or in an unheated space, where an ordinary battery would remain blocked in winter. Otherwise it works like any household storage unit: it gathers the panels' energy during the day and gives it back in the evening or during an outage.
The 5.12 kWh cover the evening consumption of a home for lighting, fridge, electronics and small appliances, and if more is needed, identical modules are added. The working current is 75 A continuous, with peaks of 101-120 A for 3 minutes and 121-180 A for 15 seconds, so it also handles appliance start-ups. The heating raises the cell temperature by about 8 degrees C per hour and extends operation into the -18...10 degrees C range, beyond the normal range of -10...50 degrees C. The round-trip efficiency exceeds 95%, meaning that of the energy put into the battery you recover more than 95%. The format is a 3.2U rack, 442 x 530 x 140 mm and 44 kg, with wall or floor mounting; the declared life is a minimum of 6000 cycles at 90% discharge, with a designed service life of up to 20 years.
LFP cells, 51.2 V rated, 100 Ah, 5.12 kWh, working range 47.6-57.6 V, round-trip efficiency over 95%. Recommended and maximum continuous charging/discharging current 75 A; discharge peaks 101-120 A for 3 min and 121-180 A for 15 s. Minimum 6000 cycles at 90% DOD, designed service life up to 20 years. Integrated heating pad, +8 degrees C/h, extended operation -18...10 degrees C, normal range -10...50 degrees C. Rack format 3.2U, 442 x 530 x 140 mm, 44 kg, wall or floor mounting. CAN and RS485 communication, with protocols for most common hybrid inverters. Expansion: 16 units per group (81.92 kWh) and up to 6 groups in a system (491.52 kWh). Certifications: UL9540 Ed.2, UL9540A, UL1973, CE, IEC 62619, UN38.3.
Suitable for a house where the battery must be installed in a garage, cellar, outbuilding or another unheated space and where winters drop below zero degrees, on a 48 V hybrid inverter.
| Cell technology | LFP (LiFePO4) |
|---|---|
| Rated voltage | 51,2 V |
| Capacity | 100 Ah |
| Rated energy | 5,12 kWh |
| Voltage range | 47,6 - 57,6 V |
| Maximum continuous current | 75 A |
| Discharge peak | 101-120 A (3 min); 121-180 A (15 s) |
| Number of cycles | >= 6000 @ 90% DOD |
| Round-trip efficiency | > 95% |
| Integrated heating | pad de incalzire, +8 grade C/h, functionare extinsa -18...10 grade C |
| Operating temperature | -10...50 grade C |
| Dimensions | 442 x 530 x 140 mm (3,2U) |
| Weight | 44 kg |
| Communication | CAN / RS485 |
| Expansion | 16 unitati/grup (81,92 kWh); 6 grupuri (491,52 kWh) |
| Certifications | UL9540 Ed.2, UL9540A, UL1973, CE, IEC 62619, UN38.3 |
10 years (designed service life up to 20 years)
Specifications confirmed from the manufacturer's datasheet
Pytes V5a is a low-voltage storage unit with LFP cells, rated voltage 51.2 V, capacity 100 Ah and rated energy 5.12 kWh. The voltage range in operation is 47.6 - 57.6 V, and the round-trip efficiency exceeds 95%.
The recommended and maximum continuous charging and discharging current is 75 A. On discharge, the battery allows peaks of 101 - 120 A for 3 minutes and 121 - 180 A for 15 seconds. The declared service life is a minimum of 6000 cycles at 90% DOD, with a designed service life of up to 20 years.
The distinctive element of the V5a version is the integrated heating pad, which raises the cell temperature by about 8 degrees C per hour and allows operation in the -18...10 degrees C range, where an ordinary LFP battery would not accept charging. The normal operating range is -10...50 degrees C. This function is important for installations in unheated spaces or outdoors.
The format is a 3.2U rack type, with dimensions 442 x 530 x 140 mm and a weight of 44 kg, with wall or floor mounting. Communication is done through CAN and RS485, with protocols for most common hybrid inverters. 16 units can be linked in a group, i.e. 81.92 kWh, and up to 6 groups in a system, i.e. 491.52 kWh. Certifications: UL9540 Ed.2, UL9540A, UL1973, CE, IEC 62619, UN38.3.