AC/DC distribution board 3~6kW three-phase - 2 strings
Solar One

AC/DC distribution board 3~6kW three-phase - 2 strings

Accessories & Smart Meters
1.775,28 RON VAT included
Excl. VAT: 1.467,17 RON · VAT (21%): 308,11 RON

Pre-wired AC and DC protection for three-phase 3-6 kW systems with the panels on 2 strings; includes the sealable 35.5 x 22.5 x 14 cm meter enclosure.

Request a quote
Source: manufacturer's datasheet
The price includes VAT 21% and is calculated transparently based on the BNR exchange rate. The final price is confirmed in the quote, subject to stock availability.
Want the complete system, with ANRE-authorised installation and prosumer file? Use the turnkey system configurator for a full quote.

Description

The distribution board is the place where the photovoltaic installation stops and protects itself. It gathers in a single enclosure the fuses and breakers on the panel side, where the current is direct, and those between the inverter and the grid, where the current is alternating and flows on three phases. It comes factory-wired, so nothing has to be improvised on site.

The two-string version is for installations in which the panels are split into two rows, connected to two MPPT inputs of the three-phase inverter. Splitting them helps on dual-pitch roofs or when one area is shaded for part of the day, because the inverter can track the maximum power point of each group separately, and the shaded group no longer drags the other one down. Each string has its own protection and disconnection circuit on the direct current side. The package includes the sealable enclosure for the distribution operator's meter, made of hard plastic, 35.5 x 22.5 x 14 cm, with holes for seals, required when prosumer installations are energised. Pre-assembled delivery shortens the execution time on site.

Intended use: three-phase photovoltaic systems 3-6 kW, DC configuration on 2 strings, with individual protection and disconnection on each row. The alternating current side is protected on three phases up to the connection point: short circuit, overload and transient overvoltages, with isolation of the installation for maintenance work. Delivered pre-assembled and wired, with a sealable meter enclosure 35.5 x 22.5 x 14 cm; the rated values of the individual devices are set by the manufacturer according to the system power.

Who it suits

Suitable for a house or a small office with a three-phase connection and a 3-6 kW system, with the panels on two roof pitches or with an area shaded for part of the day.

Terms explained

  • MPPT: The function through which the inverter permanently looks for the point where the panels deliver the most; two MPPT inputs regulate two groups of panels independently.
  • Partial shading: The situation in which only some of the panels sit in the shade, from a chimney, an antenna or a tree, and their output drops compared to the rest.
  • Overload: The passage through the cable of a current higher than the one it was sized for, which heats it up; the protection breaks the circuit before damage occurs.

Technical specifications

Intended useSisteme fotovoltaice trifazate 3-6 kW
DC configuration2 string-uri fotovoltaice
Grid typeTrifazat
Protections includedProtecție AC și DC: scurtcircuit, suprasarcină, supratensiune
Meter enclosureSigilabilă pentru operatorul de distribuție, 35,5 x 22,5 x 14 cm
Enclosure materialPlastic dur, rezistent la praf, umiditate și șocuri mecanice
Delivery modePreasamblat și cablat

Recommended applications

  • Connection of three-phase 3-6 kW photovoltaic systems with two strings of panels
  • Dual-pitch roofs or roofs with different shading areas
  • Three-phase prosumer installations requiring a sealable meter enclosure
  • Standardising the installation and shortening the execution time on site

Technical details

Generic product — standard specifications

The two-string version of the three-phase AC/DC board for 3-6 kW systems is intended for installations in which the photovoltaic modules are split into two strings, connected to two MPPT inputs of the three-phase inverter. Each string has its own protection and disconnection circuit on the direct current side, while the alternating current side is protected on three phases up to the connection point.

The assembly covers short-circuit and overload protection, transient overvoltage protection and isolation of the installation for maintenance work. Splitting into two strings is useful on dual-pitch roofs or with different partial shading between areas, allowing the inverter to track the maximum power point separately for each group of modules.

The package includes the sealable enclosure for the distribution operator's meter, with dimensions of 35.5 x 22.5 x 14 cm, made of hard and resistant plastic, fitted with special holes for applying the seals. It protects the meter against dust, moisture and mechanical shocks and prevents unauthorised access, being required when prosumer installations are energised. The board is delivered pre-assembled and wired; the rated values of the individual devices are set by the manufacturer according to the system power.