Electrical panel AC/DC 25kW three-phase - 4 strings
Solar One

Electrical panel AC/DC 25kW three-phase - 4 strings

Accessories & Smart Meters
2.972,09 RON VAT included
Excl. VAT: 2.456,27 RON · VAT (21%): 515,82 RON

Each of the 4 panel strings has its own protection, for three-phase 25 kW systems; includes the sealable meter box of 355 x 225 x 140 mm.

Request a quote
Source: manufacturer's datasheet
The price includes VAT 21% and is calculated transparently based on the BNR exchange rate. The final price is confirmed in the quote, subject to stock availability.
Want the complete system, with ANRE-authorised installation and prosumer file? Use the turnkey system configurator for a full quote.

Description

A photovoltaic protection panel does two simple things: it shuts down the installation when needed and blocks faults - short circuits or voltage peaks - before they reach the inverter and the rest of the building. It covers both the path between the panels and the inverter and the one between the inverter and the main board. In large systems, where the panels are divided into several strings, each string enters protected separately.

The set is intended for three-phase installations with an inverter of approximately 25 kW and a photovoltaic field distributed over 4 strings. The string structure matters at powers above 20 kW, where the currents and the number of modules increase: a fault on one string no longer affects the whole field, and diagnosis is done per circuit, not over the whole installation. On the alternating current side, the panel provides the separation point for maintenance and for emergency disconnection. The meter box delivered together with the panel is made of hard plastic, resistant to dust, humidity and mechanical shocks, has dimensions of 35,5 x 22,5 x 14 cm and special holes for the application of seals by the distribution operator, according to the prosumer connection procedure.

Product code 25-AC/DC-4str-tri, three-phase grid 3P+N, system/inverter power 25 kW, 4 DC string inputs, each with its own protection circuit against overvoltages and short circuits. The AC section protects the circuit between the inverter and the main board against short circuits, overloads and overvoltages, on a 3P+N grid. Sealable meter box of hard plastic, 355 x 225 x 140 mm, with holes for seals; intended use: on-grid photovoltaic systems of the prosumer type.

Who it suits

Suitable for a small company or a large residential property with a three-phase connection and a system of about 25 kW, with the panels organised in four strings.

Terms explained

  • Photovoltaic field: All the panels of an installation, grouped in several strings that enter the inverter separately.
  • Per-circuit diagnosis: The possibility of finding the problem by checking a single panel string, instead of shutting down and checking the whole installation.
  • Emergency disconnection: The rapid shutdown of the whole installation from a single place, in case of a fault or of intervention by the fire brigade.

Technical specifications

Product code25-AC/DC-4str-tri
Grid typeTrifazat (3F+N)
System / inverter power25 kW
DC inputs (strings)4
DC protectionsîmpotriva supratensiunilor și a scurtcircuitelor
AC protectionsîmpotriva supratensiunilor, fluctuațiilor și a scurtcircuitelor
Meter boxsigilabilă, plastic dur, cu orificii pentru sigilii
Meter box dimensions355 x 225 x 140 mm
Intended usesisteme fotovoltaice on-grid / prosumator

Recommended applications

  • Three-phase on-grid photovoltaic systems of about 25 kW, commercial or large residential
  • Photovoltaic fields organised in 4 strings, with a multi-MPPT inverter
  • Connecting prosumer installations, with a sealable space for the DO meter
  • Protection against overvoltages and short circuits on the direct current and alternating current sides

Technical details

Generic product — standard specifications

The set (product code 25-AC/DC-4str-tri) includes the AC/DC protection panel for photovoltaic systems and the sealable box for the meter of the distribution operator, being intended for three-phase installations with an inverter of approximately 25 kW and a photovoltaic field distributed over 4 strings.

On the direct current side, each of the 4 strings enters the panel through its own protection circuit against overvoltages and short circuits. This per-string structure is important at powers above 20 kW, where the currents and the number of modules increase: a fault on one string no longer affects the whole field, and diagnosis is done per circuit, not over the whole installation.

The alternating current section protects the circuit between the inverter and the main board against short circuits, overloads and overvoltages, on a three-phase 3P+N grid, and provides the separation point for maintenance and for emergency disconnection. The panel thus manages the fluctuations and overvoltages on both energy flows and allows the control and verification of the operation of the system.

The meter box delivered together with the panel is made of hard plastic, resistant to dust, humidity and mechanical shocks, has dimensions of 35,5 x 22,5 x 14 cm and special holes for the application of seals by the distribution operator, according to the prosumer connection procedure.