AC/DC electrical board 15kW three-phase - 2 strings
Solar One

AC/DC electrical board 15kW three-phase - 2 strings

Accessories & Smart Meters
1.978,47 RON VAT included
Excl. VAT: 1.635,10 RON · VAT (21%): 343,37 RON

A single point of protection and disconnection for a three-phase system of up to 15 kW with 2 strings; includes the sealable meter box of 355 x 225 x 140 mm.

Request a quote
Source: manufacturer's datasheet
The price includes VAT 21% and is calculated transparently based on the BNR exchange rate. The final price is confirmed in the quote, subject to stock availability.
Want the complete system, with ANRE-authorised installation and prosumer file? Use the turnkey system configurator for a full quote.

Description

In a photovoltaic system, the energy travels on two paths: from the panels to the inverter, with direct current, and from the inverter to the building's board, with alternating current. This board is the single point at which both paths are protected and can be switched off. Its main role is to take the voltage surges that appear from lightning striking nearby or from switching on the grid, before they reach the input stage of the inverter - the most frequent cause of failure in roof installations.

The set is dimensioned for three-phase installations with an inverter of up to 15 kW and a panel field organised in 2 strings. Each string enters the board protected against surges and short circuits, before the MPPT inputs of the inverter. On the alternating current side, the board becomes the place from which the installation is disconnected both for maintenance work and for disconnection in the event of a fault. Together with the board, the box for the distribution operator's meter is supplied, of hard plastic, with dimensions 35.5 x 22.5 x 14 cm and holes for seals - a mandatory requirement in the prosumer's connection file. The box protects the meter from dust, humidity and mechanical shocks.

Product code 15-AC/DC-2str-tri, three-phase grid 3F+N, system/inverter power up to 15 kW, 2 DC string inputs. DC protections against surges and short circuits, installed before the MPPT inputs of the inverter; AC protections against surges, fluctuations and short circuits on the circuit between the inverter and the consumer's main board. Sealable meter box of hard plastic, 355 x 225 x 140 mm, with holes for seals, intended for on-grid prosumer-type systems.

Who it suits

Suitable for a large house or a headquarters with a three-phase 3F+N connection and an inverter of up to 15 kW, with the panels split over two strings.

Terms explained

  • 3F+N: Three phases plus neutral, that is the usual three-phase connection of buildings with higher consumption.
  • Inverter input stage: The first electronic part that the current coming from the panels meets; it is the component most exposed to voltage peaks.
  • Disconnection point: The place from which the entire installation can be de-energised, both for planned work and in the event of a fault.

Technical specifications

Product code15-AC/DC-2str-tri
Grid typeTrifazat (3F+N)
System / inverter powerup to 15 kW
DC inputs (strings)2
DC protectionsagainst surges and short circuits
AC protectionsagainst surges, fluctuations and short circuits
Meter boxsealable, hard plastic, with holes for seals
Meter box dimensions355 x 225 x 140 mm
Intended useon-grid / prosumer photovoltaic systems

Recommended applications

  • Three-phase residential on-grid photovoltaic systems of up to 15 kW
  • Connection of prosumer installations to the distribution grid, with a sealable meter
  • Protection of the inverter and the modules against atmospheric and switching surges
  • A single point of disconnection and protection between the photovoltaic field, the inverter and the main board

Technical details

Generic product — standard specifications

The assembly (product code 15-AC/DC-2str-tri) brings together in a single point the protection board for the direct current and the alternating current sides of a three-phase on-grid photovoltaic system, together with the sealable box intended for the distribution operator's meter. It is dimensioned for installations with a three-phase inverter of up to 15 kW and a photovoltaic field organised in 2 strings.

On the direct current side, the board takes the 2 module strings and protects them against surges and short circuits, before they reach the MPPT inputs of the inverter. The role of this section is to limit the energy of the surges induced by indirect atmospheric discharges and by switching on the grid, which otherwise discharge directly into the input stage of the inverter - the most frequent cause of failure in roof installations.

On the alternating current side, the board provides protection of the circuit between the inverter and the consumer's main board against short circuits, overloads and surges, on a three-phase 3F+N grid. In practice, the board becomes the single point of disconnection and protection of the installation, both for maintenance interventions and for disconnection in the event of a fault.

The meter box is made of hard plastic, resistant to dust, humidity and mechanical shocks, has dimensions of 35.5 x 22.5 x 14 cm and features special holes for the application of the seals by the distribution operator - a mandatory requirement in the prosumer's connection file.